Sprinkler Inspections That Leave Nothing Unclear

Quarterly, annual and five-year inspection, testing and maintenance under NFPA 25, with deficiencies ranked, photographed and quoted so you can act on them.

NFPA 25 programsDigital reportsRecurring scheduling

Overview

An inspection program, not just a visit

NFPA 25 assigns tasks to different intervals: weekly, monthly, quarterly, annual and multi-year. We map every task to your systems and put them on one recurring calendar, so nothing falls between visits.

Each visit ends with a report that separates impairments, deficiencies and recommendations, with photos and a quote for any corrective work.

  • Control valve, gauge and alarm device inspections
  • Main drain and waterflow alarm tests
  • Dry pipe trip tests and compressor checks
  • Five-year internal pipe assessments
  • Gauge replacement or calibration
  • Sprinkler sampling when due
Sprinkler Inspection & Testing overview
One calendar

Every NFPA 25 task mapped to your building.

What we do

Everything NFPA 25 expects, scheduled for you

Get A Quote

01

Quarterly & Annual Visits

Scheduled automatically on your building's calendar, with reminders before each visit.

02

Testing

Main drains, waterflow alarms, dry pipe trips and backflow forward-flow tests.

03

Five-Year Assessments

Internal pipe inspections for obstructions, corrosion and debris, plus check valve internals.

04

Clear Reports

Impairments, deficiencies and recommendations separated and photographed.

05

Corrective Work

A quote for every deficiency and crews to complete the repairs.

06

Owner Training

We show your team the weekly and monthly checks expected between our visits.

Standards & frequency

Typical NFPA 25 tasks for wet and dry systems

We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.

ComponentTaskTypical frequency
Control valvesInspect position and conditionWeekly if sealed; monthly if locked or electrically supervised
Waterflow alarm devicesTestQuarterly (mechanical); semiannually (vane and pressure switch)
Sprinklers & visible pipingInspect from floor levelAnnually
Main drainTestAnnually, more often for some supply arrangements
Dry pipe valveTrip testAnnually; full-flow trip every 3 years
GaugesReplace or calibrateEvery 5 years
Internal pipingAssessmentEvery 5 years

Summary of commonly adopted NFPA 25 editions. Your adopted edition, local amendments and AHJ determine actual requirements.

How it works

A clear process from first call to closeout

01

Survey your systems

We document risers, valves, devices and system types on the first visit.

02

Build the calendar

Every task is mapped to a recurring schedule with reminders.

03

Inspect, test & document

Findings are photographed and ranked in a clear report.

04

Correct & close out

Approved repairs are scheduled, completed and documented.

Questions

Sprinkler Inspection & Testing FAQs

Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.

Who is responsible for NFPA 25 inspections?

NFPA 25 places responsibility for inspection, testing and maintenance on the property owner or their designated representative. Owners usually contract the work, but the obligation and the records stay with the owner.

What is the difference between an impairment and a deficiency?

An impairment means a system, or part of it, is out of service. A deficiency is a condition that affects or could affect performance without taking the system out of service. Impairments need immediate action and notification; deficiencies get prioritized repairs.

Can my staff do the weekly and monthly checks?

Yes. Many owners handle weekly and monthly visual inspections in-house. We provide checklists and training, and we handle the quarterly, annual and multi-year tasks.

How do we receive reports?

Reports are posted to your customer portal after each visit and emailed to your contacts. They are also what your fire marshal and insurer will ask to see.

Related services

Often paired with this service

All services
Fire Pumps & Standpipes

Fire Pumps & Standpipes

Churn tests, annual flow tests and standpipe testing.

Learn more
Backflow Testing & Repair

Backflow Testing & Repair

Annual testing, rebuilds and utility paperwork.

Learn more
Fire Sprinkler Systems

Fire Sprinkler Systems

Design, installation and retrofits for new and existing buildings.

Learn more

System impairment, leak or alarm trouble?

Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.

218-262-9553

Emergency service