Fire Protection Glossary

Plain-language definitions of the terms you will see in inspection reports, quotes and code documents.

A

AHJ (Authority Having Jurisdiction)
The organization or official responsible for enforcing codes and approving equipment and installations, usually the local fire marshal or building official.
Alarm check valve
A check valve on a wet sprinkler riser that signals waterflow when a sprinkler opens.
Antifreeze system
A wet system containing a listed antifreeze solution to protect small unheated areas.
Aspirating smoke detection
Detection that draws air samples through pipes to a sensitive detector for very early warning.

B

Backflow preventer
An assembly that prevents sprinkler system water from flowing back into the public water supply.
BDA (Bi-Directional Amplifier)
The amplifier at the heart of most emergency responder radio coverage systems.

C

Central station
A monitoring center that receives alarm, supervisory and trouble signals and dispatches responders.
Churn test
A no-flow test that runs a fire pump without flowing water through the system.
Clean agent
A gaseous suppression agent that leaves no residue, used to protect sensitive equipment.
Control valve
A valve that controls water supply to a sprinkler system; it must be kept open and supervised.

D

Deficiency
A condition that affects or could affect system performance without taking it out of service.
Deluge system
A system with open sprinklers that all discharge when the detection system operates.
Dry pipe system
A system holding pressurized air in the piping, used where water could freeze.

E

ERRCS
Emergency responder radio coverage system, which provides public safety radio signal inside buildings.
ESFR
Early suppression fast response sprinklers designed to suppress high-challenge storage fires.

F

FDC (Fire Department Connection)
An exterior connection where firefighters pump water into the sprinkler or standpipe system.
Fire damper
A device in ductwork that closes automatically to stop fire spreading through HVAC ducts.
Fire pump
A pump that boosts water pressure for sprinklers and standpipes.
Fire watch
Trained people patrolling an area when fire protection systems are out of service.
Flow test
A test that measures water flow and pressure available from a hydrant or system.
Fusible link
A heat-sensitive link that separates at a set temperature to operate a damper, door or suppression system.

H

Hydraulic calculations
Engineering calculations showing a sprinkler system can deliver the required water.
Hydrostatic test
A pressure test of piping or extinguisher shells to verify strength and tightness.

I

Impairment
A condition where a fire protection system, or part of one, is out of service.
In-rack sprinklers
Sprinklers installed within storage racks to reach fires inside the rack.
Inspector's test valve
A valve used to simulate one sprinkler flowing in order to test waterflow alarms.
ITM
Inspection, testing and maintenance, the ongoing work required to keep systems reliable.

J

Jockey pump
A small pump that maintains system pressure so the fire pump does not start unnecessarily.

M

Main drain test
A test that flows water at the riser to check the water supply and valve condition.

N

NFPA
The National Fire Protection Association, which publishes most fire protection codes and standards.
Notification appliance
A horn, strobe, speaker or other device that alerts occupants.

P

Pre-action system
A system that requires a detection event before water enters the piping.
PIV (Post Indicator Valve)
An underground valve with an above-ground indicator showing whether it is open or shut.

R

Reduced pressure zone assembly
A backflow assembly with a relief valve used for higher-hazard connections.
Riser
The vertical pipe and valve assembly where water enters a sprinkler system.

S

Standpipe
A pipe system with hose connections that firefighters use inside buildings.
Supervisory signal
A signal indicating an abnormal condition, such as a closed valve or low air pressure.

T

Tamper switch
A switch that reports when a control valve is moved from the open position.
Trouble signal
A signal indicating a fault in the fire alarm system, such as power loss or a wiring problem.

V

Voice evacuation
A fire alarm system that delivers spoken instructions to occupants.

W

Waterflow switch
A device that detects water moving in sprinkler piping and triggers an alarm.
Wet pipe system
A sprinkler system with water in the piping at all times.