Glossary
Fire Protection Glossary
Plain-language definitions of the terms you will see in inspection reports, quotes and code documents.
A
- AHJ (Authority Having Jurisdiction)
- The organization or official responsible for enforcing codes and approving equipment and installations, usually the local fire marshal or building official.
- Alarm check valve
- A check valve on a wet sprinkler riser that signals waterflow when a sprinkler opens.
- Antifreeze system
- A wet system containing a listed antifreeze solution to protect small unheated areas.
- Aspirating smoke detection
- Detection that draws air samples through pipes to a sensitive detector for very early warning.
B
- Backflow preventer
- An assembly that prevents sprinkler system water from flowing back into the public water supply.
- BDA (Bi-Directional Amplifier)
- The amplifier at the heart of most emergency responder radio coverage systems.
C
- Central station
- A monitoring center that receives alarm, supervisory and trouble signals and dispatches responders.
- Churn test
- A no-flow test that runs a fire pump without flowing water through the system.
- Clean agent
- A gaseous suppression agent that leaves no residue, used to protect sensitive equipment.
- Control valve
- A valve that controls water supply to a sprinkler system; it must be kept open and supervised.
D
- Deficiency
- A condition that affects or could affect system performance without taking it out of service.
- Deluge system
- A system with open sprinklers that all discharge when the detection system operates.
- Dry pipe system
- A system holding pressurized air in the piping, used where water could freeze.
E
- ERRCS
- Emergency responder radio coverage system, which provides public safety radio signal inside buildings.
- ESFR
- Early suppression fast response sprinklers designed to suppress high-challenge storage fires.
F
- FDC (Fire Department Connection)
- An exterior connection where firefighters pump water into the sprinkler or standpipe system.
- Fire damper
- A device in ductwork that closes automatically to stop fire spreading through HVAC ducts.
- Fire pump
- A pump that boosts water pressure for sprinklers and standpipes.
- Fire watch
- Trained people patrolling an area when fire protection systems are out of service.
- Flow test
- A test that measures water flow and pressure available from a hydrant or system.
- Fusible link
- A heat-sensitive link that separates at a set temperature to operate a damper, door or suppression system.
H
- Hydraulic calculations
- Engineering calculations showing a sprinkler system can deliver the required water.
- Hydrostatic test
- A pressure test of piping or extinguisher shells to verify strength and tightness.
I
- Impairment
- A condition where a fire protection system, or part of one, is out of service.
- In-rack sprinklers
- Sprinklers installed within storage racks to reach fires inside the rack.
- Inspector's test valve
- A valve used to simulate one sprinkler flowing in order to test waterflow alarms.
- ITM
- Inspection, testing and maintenance, the ongoing work required to keep systems reliable.
J
- Jockey pump
- A small pump that maintains system pressure so the fire pump does not start unnecessarily.
M
- Main drain test
- A test that flows water at the riser to check the water supply and valve condition.
N
- NFPA
- The National Fire Protection Association, which publishes most fire protection codes and standards.
- Notification appliance
- A horn, strobe, speaker or other device that alerts occupants.
P
- Pre-action system
- A system that requires a detection event before water enters the piping.
- PIV (Post Indicator Valve)
- An underground valve with an above-ground indicator showing whether it is open or shut.
R
- Reduced pressure zone assembly
- A backflow assembly with a relief valve used for higher-hazard connections.
- Riser
- The vertical pipe and valve assembly where water enters a sprinkler system.
S
- Standpipe
- A pipe system with hose connections that firefighters use inside buildings.
- Supervisory signal
- A signal indicating an abnormal condition, such as a closed valve or low air pressure.
T
- Tamper switch
- A switch that reports when a control valve is moved from the open position.
- Trouble signal
- A signal indicating a fault in the fire alarm system, such as power loss or a wiring problem.
V
- Voice evacuation
- A fire alarm system that delivers spoken instructions to occupants.
W
- Waterflow switch
- A device that detects water moving in sprinkler piping and triggers an alarm.
- Wet pipe system
- A sprinkler system with water in the piping at all times.