Closer, latch, hinge, gap and label checks for every rated opening.

Fire Door Inspections
Annual inspection and testing of swinging, rolling and sliding fire door assemblies under NFPA 80, with photo reports and repair crews to close out deficiencies.
Overview
Fire-rated doors hold back fire and smoke so people can get out and firefighters can get in. Wedges, worn closers, missing labels and damaged frames all undermine that rating.
We inspect each assembly, number it in your inventory and document every deficiency with a photo and a recommended repair. Our crews can then make the repairs that keep the assembly compliant.

Every rated opening tracked year to year.
What we do
01
Closer, latch, hinge, gap and label checks for every rated opening.
02
Drop testing, governor checks and resets for rolling steel doors.
03
Inspection of smoke-resistant assemblies in corridors and elevator lobbies.
04
A numbered inventory with location, rating and status for each opening.
05
Hardware, closer and gasket repairs that keep the assembly compliant.
06
Photo documentation formatted for fire marshals and accreditation surveys.
Standards & frequency
We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.
| Assembly | Standard | Typical frequency |
|---|---|---|
| Fire door assemblies | NFPA 80 | Inspection and testing annually |
| Smoke door assemblies | NFPA 105 | Inspection and testing annually |
| Rolling fire doors | NFPA 80 | Annual drop test and reset |
Summary of commonly adopted editions. Your AHJ and accreditation body determine actual requirements.
How it works
01
Every rated opening numbered with its location and rating.
02
Each assembly checked against NFPA 80 criteria.
03
Deficiencies listed by door with photos and repairs.
04
Repairs made and the door re-inspected.
Questions
Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.
Doors that do not self-close or latch, excessive gaps, wedges and hold-opens not tied to the fire alarm, painted-over or missing labels, and field modifications such as added hardware.
Only with hold-open devices that release automatically when the fire alarm activates. Wedges and kick-down stops defeat the door.
Repairs should use listed parts and methods that preserve the rating. Some repairs require the manufacturer or a labeling service, and we tell you when that is the case.
It depends on the number of openings. We build an inventory on the first visit, which makes later inspections faster.
Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.