Data & Telecom Rooms
Clean agent with early-warning detection and controlled shutdowns.

Special Hazard Suppression
Clean agent, inert gas, CO2, foam and pre-engineered systems for data rooms, archives, electrical rooms, paint booths and process equipment.
Overview
Some spaces need protection that won't damage equipment, records or processes. Special hazard systems detect a fire early and discharge an agent sized to the room, often with interlocks that shut down HVAC, power and doors.
We evaluate the hazard, recommend an agent and handle design, installation, room integrity testing and ongoing service.

Door fan testing confirms the room holds agent.
What we do
01
Clean agent with early-warning detection and controlled shutdowns.
02
Protection that leaves paper and media intact.
03
Agent and detection options for switchgear and energy storage spaces.
04
Pre-engineered dry chemical systems and interlocks for booths, ovens and dust collection.
05
Foam for flammable liquid hazards, including transitions away from PFAS-containing foam.
06
Door fan testing to confirm the room holds the design concentration.
Standards & frequency
We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.
| System | Standard | Typical frequency |
|---|---|---|
| Clean agent & inert gas | NFPA 2001 | Agent quantity and pressure checked semiannually; full inspection annually |
| Enclosure integrity | NFPA 2001 | Enclosure inspected annually; retest after changes |
| Carbon dioxide | NFPA 12 | Per standard and manufacturer schedule |
| Dry chemical (paint booths) | NFPA 17 | Inspection and maintenance semiannually |
| Foam systems | NFPA 11 / NFPA 25 | Annual inspection and foam concentrate testing |
Summary of commonly adopted editions. Manufacturer instructions and your AHJ determine actual requirements.
How it works
01
What is in the room, how it is used and what it can tolerate.
02
Agent selection, concentration and interlock design.
03
Installation, integrity testing and full functional test.
04
Agent checks, inspections and detection testing on schedule.
Questions
Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.
Clean agents used in occupied spaces are applied at concentrations evaluated for occupant exposure under NFPA 2001. Systems still include pre-discharge alarms and time delays so people can leave before discharge.
Many states are restricting PFAS-containing firefighting foam. If your system uses AFFF, we can review your hazard and your options for moving to fluorine-free foam.
Clean agent systems rely on holding a concentration for a period of time. Gaps around doors, ceilings and penetrations let agent escape. A door fan test verifies the room can hold it.
Most systems shut down HVAC and close dampers so the agent stays in the room. Power shutdown depends on the hazard and is designed with your engineer and IT team.
Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.