Special Hazard Suppression hero

Special Hazard Suppression

Special Hazard Suppression for Spaces Water Can't Protect

Clean agent, inert gas, CO2, foam and pre-engineered systems for data rooms, archives, electrical rooms, paint booths and process equipment.

Clean agent & inert gasRoom integrity testingSemiannual checks

Overview

Suppression engineered around the asset inside

Some spaces need protection that won't damage equipment, records or processes. Special hazard systems detect a fire early and discharge an agent sized to the room, often with interlocks that shut down HVAC, power and doors.

We evaluate the hazard, recommend an agent and handle design, installation, room integrity testing and ongoing service.

  • Clean agent systems (FK-5-1-12, HFC-227ea)
  • Inert gas systems
  • Carbon dioxide for unoccupied hazards
  • Foam systems and fluorine-free transitions
  • Paint booth and dust collector systems
  • Aspirating early-warning smoke detection
Special Hazard Suppression overview
Integrity tested

Door fan testing confirms the room holds agent.

What we do

Protection designed for sensitive and high-risk spaces

Get A Quote

01

Data & Telecom Rooms

Clean agent with early-warning detection and controlled shutdowns.

02

Archives & Records

Protection that leaves paper and media intact.

03

Electrical & Battery Rooms

Agent and detection options for switchgear and energy storage spaces.

04

Paint Booths & Process

Pre-engineered dry chemical systems and interlocks for booths, ovens and dust collection.

05

Foam Systems

Foam for flammable liquid hazards, including transitions away from PFAS-containing foam.

06

Room Integrity Testing

Door fan testing to confirm the room holds the design concentration.

Standards & frequency

Typical special hazard service intervals

We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.

SystemStandardTypical frequency
Clean agent & inert gasNFPA 2001Agent quantity and pressure checked semiannually; full inspection annually
Enclosure integrityNFPA 2001Enclosure inspected annually; retest after changes
Carbon dioxideNFPA 12Per standard and manufacturer schedule
Dry chemical (paint booths)NFPA 17Inspection and maintenance semiannually
Foam systemsNFPA 11 / NFPA 25Annual inspection and foam concentrate testing

Summary of commonly adopted editions. Manufacturer instructions and your AHJ determine actual requirements.

How it works

A clear process from first call to closeout

01

Hazard assessment

What is in the room, how it is used and what it can tolerate.

02

Agent & design

Agent selection, concentration and interlock design.

03

Install & commission

Installation, integrity testing and full functional test.

04

Semiannual service

Agent checks, inspections and detection testing on schedule.

Questions

Special Hazard Suppression FAQs

Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.

Is clean agent safe for occupied rooms?

Clean agents used in occupied spaces are applied at concentrations evaluated for occupant exposure under NFPA 2001. Systems still include pre-discharge alarms and time delays so people can leave before discharge.

Can we keep using our existing AFFF foam?

Many states are restricting PFAS-containing firefighting foam. If your system uses AFFF, we can review your hazard and your options for moving to fluorine-free foam.

Why does the room need an integrity test?

Clean agent systems rely on holding a concentration for a period of time. Gaps around doors, ceilings and penetrations let agent escape. A door fan test verifies the room can hold it.

What happens to HVAC and power during a discharge?

Most systems shut down HVAC and close dampers so the agent stays in the room. Power shutdown depends on the hazard and is designed with your engineer and IT team.

Related services

Often paired with this service

All services
Fire Alarm & Detection

Fire Alarm & Detection

Panels, detection, notification and voice evacuation.

Learn more
Alarm Monitoring

Alarm Monitoring

Central station monitoring over cellular and IP paths.

Learn more
Kitchen Hood Suppression

Kitchen Hood Suppression

Wet chemical systems for commercial kitchens.

Learn more

System impairment, leak or alarm trouble?

Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.

218-262-9553

Emergency service