Fire & Smoke Damper Testing

Fire and Smoke Damper Inspection and Testing

Damper inventories, operational testing, repairs and reports under NFPA 80 and NFPA 105 for hospitals, schools, offices and multifamily buildings.

NFPA 80 & 105Damper inventoriesRepairs & access

Overview

Hidden in the ductwork, required by code

Fire and smoke dampers close inside ductwork to keep fire and smoke from spreading through a building's HVAC system. Because they are hidden above ceilings, they are often forgotten until an inspector asks for test records.

We locate and label each damper, operate it, document its condition with photos, and repair or replace failed links, actuators and access panels.

  • Fire damper drop testing
  • Smoke damper actuation testing
  • Combination fire/smoke dampers
  • Damper inventories and labeling
  • Access panel installation
  • Fusible link and actuator replacement
Fire & Smoke Damper Testing overview
Numbered inventory

Every damper located and labeled.

What we do

Damper services

Get A Quote

01

Inventory

Locate dampers from drawings and field surveys, then label each one.

02

Fire Dampers

Remove the link, verify full closure and reset.

03

Smoke Dampers

Actuation testing from the fire alarm or control system.

04

Repairs

Links, actuators, springs and frames repaired or replaced.

05

Access Panels

New access doors where dampers can't be reached.

06

Reports

Damper-by-damper records with photos for surveyors.

Standards & frequency

Typical damper testing frequency

We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.

DamperStandardTypical frequency
Fire dampersNFPA 801 year after installation, then every 4 years
Smoke dampersNFPA 1051 year after installation, then every 4 years
Dampers in hospitalsNFPA 80 / 105Every 6 years after the first test

Summary of commonly adopted editions. Accreditation bodies and your AHJ may set additional requirements.

How it works

A clear process from first call to closeout

01

Locate

Drawings and field survey to find each damper.

02

Label & test

Every damper numbered, operated and photographed.

03

Report

Pass/fail by damper with repair recommendations.

04

Repair

Failed dampers repaired and retested.

Questions

Fire & Smoke Damper Testing FAQs

Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.

How often do dampers need testing?

Commonly one year after installation and then every four years, or every six years in hospitals, under NFPA 80 and NFPA 105.

What if a damper can't be reached?

We document it and can install an access panel so it can be tested.

Do you test smoke control systems?

We test smoke dampers as part of damper programs. Full smoke control system testing is coordinated with your mechanical and controls contractors.

Will testing disrupt occupants?

Most testing happens above ceilings with minimal disruption. Healthcare work follows infection control procedures.

Related services

Often paired with this service

All services
Fire Door Inspections

Fire Door Inspections

Annual NFPA 80 inspections, drop tests and repairs.

Learn more
Fire Alarm & Detection

Fire Alarm & Detection

Panels, detection, notification and voice evacuation.

Learn more
Emergency & Exit Lighting

Emergency & Exit Lighting

Monthly and 90-minute tests, batteries and fixtures.

Learn more

System impairment, leak or alarm trouble?

Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.

218-262-9553

Emergency service