Impairments
A system or part of it is out of service. We tag it, notify the right people and help you plan fire watch until it is restored.

Inspections & Compliance
Every required inspection and test for every system, on one recurring calendar, with reports your fire marshal, insurer and auditors can read at a glance.
How the program works
Fire codes and NFPA standards place responsibility for inspection, testing and maintenance on the building owner. Different systems carry different intervals, and missing one can affect insurance, occupancy and safety.
We survey your systems once, build a calendar of every required task, and run it for you: reminders before each visit, technicians who know your building, and reports posted the same week.
Sample report layout
Wet system · Riser 1 · NFPA 25
| Component | Finding | Status |
|---|---|---|
| Control valves | Inspected | Pass |
| Waterflow alarm | Tested | Pass |
| Main drain | Tested | Pass |
| Sprinklers, 3rd floor | Paint on 2 heads | Deficiency |
| Gauges | Due for replacement | Recommend |
Illustrative example of how findings are organized in Riserline reports.
Compliance calendar
The tasks we build into a typical commercial building calendar.
Schedule service| System | Standard | Typical cadence |
|---|---|---|
| Wet & dry sprinkler systems | NFPA 25 | Valves weekly/monthly; alarms quarterly or semiannually; annual inspection; 5-year internal assessment |
| Standpipes & hose systems | NFPA 25 | Annual inspection; flow test and dry standpipe hydrostatic test every 5 years |
| Fire pumps | NFPA 25 | Churn test weekly or monthly; annual flow test |
| Private hydrants & mains | NFPA 25 | Hydrants inspected and flowed annually; mains flow-tested every 5 years |
| Backflow assemblies | NFPA 25 / utility | Annual test and forward-flow test; 5-year internal inspection |
| Fire alarm & detection | NFPA 72 | Annual device and panel testing; batteries semiannually; detector sensitivity every 2 years |
| Portable extinguishers | NFPA 10 | Monthly visual; annual maintenance; 6-year and hydrostatic intervals by type |
| Kitchen hood suppression | NFPA 96 / 17A | Inspection and maintenance every 6 months |
| Clean agent systems | NFPA 2001 | Agent and pressure semiannually; annual inspection |
| Emergency & exit lighting | NFPA 101 | Monthly 30-second test; annual 90-minute test |
| Fire & smoke doors | NFPA 80 / 105 | Annual inspection and testing |
Summary of commonly adopted NFPA editions for reference only. Adopted editions, local amendments, manufacturer instructions and your authority having jurisdiction (AHJ) determine actual requirements.
Reports
A system or part of it is out of service. We tag it, notify the right people and help you plan fire watch until it is restored.
Conditions that affect or could affect performance. Each one is photographed, ranked and quoted.
Items that are not deficiencies today but are worth planning for, such as aging components.
Deficiency follow-up
Findings posted with photos within days of the visit.
A clear quote for each deficiency, grouped by priority.
Approve in the portal or by email and we schedule the work.
Repairs documented and the report updated.

Customer portal
Download reports, see what is due next, approve quotes and share access with your property team or insurer.
Questions
Confirm access to risers, pump rooms, electrical rooms and tenant spaces, and let tenants know about alarm testing. Your coordinator sends a checklist before each visit.
Yes. We combine visits where intervals line up, such as annual sprinkler and alarm testing, to reduce disruption and coordinate signals with your monitoring company.
Send us the inspection report. We will review each item, quote the corrections and provide documentation you can submit when the work is complete.
Your reports stay in your portal for as long as you are a customer, and you can download them at any time.
Send us your current reports and we'll show you what is due and when.