Alarm Monitoring

Fire Alarm Monitoring That Doesn't Depend on a Copper Line

Central station monitoring through cellular and IP communicators, with an upgrade path for buildings still relying on traditional phone lines.

Cellular & IP pathsAlarm, supervisory & troubleEvent history

Overview

Signals that reach the right people, every time

Monitoring sends alarm, supervisory and trouble signals from your fire alarm panel to a central station that notifies the fire department and your contacts. The communication path matters as much as the panel.

As carriers retire copper phone service, many buildings are moving their communicators to cellular or IP. We assess your panel, install a compatible communicator and handle the account transfer.

  • Alarm signals dispatched to the fire department
  • Supervisory signals routed to your team
  • Trouble signals routed for service
  • Cellular and IP communicator installation
  • Contact list and call-order management
  • Event history on request
Alarm Monitoring overview
Communicator upgrades

Planned before the copper line is cut.

What we do

Monitoring set up, tested and kept current

Get A Quote

01

Communicator Upgrades

Replace dialers on copper lines with cellular or IP communicators compatible with your panel.

02

Central Station Service

Around-the-clock monitoring with dispatch to your local fire department.

03

Call Lists

Contacts and escalation order kept current as your staff changes.

04

Account Takeovers

Switching providers? We transfer the account and test every signal path.

05

Signal Testing

Verification that every alarm, supervisory and trouble signal arrives correctly.

06

Event Reports

Alarm and trouble history for insurers, audits and post-incident reviews.

Standards & frequency

What monitoring watches for

We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.

SignalTypical responseExamples
AlarmFire department dispatched, then building contactsSmoke detector, waterflow switch, pull station
SupervisoryBuilding contacts notifiedValve tamper, low air on a dry system, fire pump running
TroubleBuilding contacts and service notifiedAC power loss, ground fault, communication failure

Response procedures follow your account setup, NFPA 72 and local dispatch requirements.

How it works

A clear process from first call to closeout

01

Panel & path survey

We confirm panel compatibility and your current communication path.

02

Communicator install

Cellular or IP communicator installed and programmed.

03

Account setup & test

Contacts loaded and every signal type tested end to end.

04

Ongoing monitoring

Around-the-clock monitoring with annual signal verification.

Questions

Alarm Monitoring FAQs

Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.

Our phone company is retiring our copper lines. What should we do?

Contact us before the line is disconnected. We confirm whether your panel can accept a cellular or IP communicator, install it, transfer monitoring and test every signal so there is no gap in coverage.

Is a single cellular communicator acceptable?

Current NFPA 72 editions recognize cellular and IP communication paths, and many jurisdictions accept a supervised cellular communicator. Requirements depend on your adopted code edition and your AHJ, which we confirm before installation.

Who gets called when an alarm comes in?

For fire alarms, the central station dispatches the fire department first and then calls your contact list. Supervisory and trouble signals go to your contacts and to us for service.

Can you take over monitoring from our current provider?

Usually, yes. We review your contract terms and panel programming, then schedule a cutover and test.

Related services

Often paired with this service

All services
Fire Alarm & Detection

Fire Alarm & Detection

Panels, detection, notification and voice evacuation.

Learn more
24/7 Emergency Service

24/7 Emergency Service

Around-the-clock response to leaks and outages.

Learn more
Sprinkler Inspection & Testing

Sprinkler Inspection & Testing

NFPA 25 inspection, testing and maintenance programs.

Learn more

System impairment, leak or alarm trouble?

Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.

218-262-9553

Emergency service