Inspection, testing and maintenance of foam and foam-water systems.

Foam Systems & Transitions
Foam-water sprinkler and foam systems for flammable liquids, hangars and loading racks, plus planning and execution for moving from legacy AFFF to fluorine-free foam.
Overview
Foam systems protect flammable and combustible liquid hazards that water alone can't control. Many of those systems were built for aqueous film-forming foam (AFFF), which contains PFAS chemicals.
Minnesota and many other states now restrict PFAS-containing firefighting foam. Switching to fluorine-free foam is often more than a concentrate swap: proportioners, discharge devices and design densities may need to change.

Assessment before any concentrate change.
What we do
01
Inspection, testing and maintenance of foam and foam-water systems.
02
Annual concentrate samples sent for laboratory analysis.
03
Inventory and review of systems that still use AFFF.
04
Design changes and installation for fluorine-free foam.
05
Proportioner testing, repair and replacement.
06
Records for insurers and environmental compliance teams.
Standards & frequency
We build these intervals into your service calendar, so tasks happen on time and records are ready when your fire marshal or insurer asks.
| Item | Standard | Typical frequency |
|---|---|---|
| Foam systems | NFPA 11 | Inspection and testing per standard and manufacturer |
| Foam-water sprinklers | NFPA 25 | Annual inspection and testing |
| Foam concentrate | NFPA 11 / NFPA 25 | Annual sample testing |
| Proportioning | NFPA 25 | Annual proportioning test |
PFAS rules vary by state and are changing. Confirm requirements with your environmental team and AHJ.
How it works
01
Which systems and tanks hold AFFF.
02
Hazard, design and compatibility review.
03
Clean, modify and refill with fluorine-free foam.
04
Acceptance testing and documentation.
Questions
Have a question about your building? Call 218-262-9553 or send a request and a specialist will follow up.
Not always. Fluorine-free foams behave differently and may require different proportioning, discharge devices or application rates. An assessment comes first.
It must be handled and disposed of properly. We coordinate with licensed disposal contractors.
Typically once a year, with samples sent to a laboratory.
Yes. Proportioners, discharge devices and concentrate all need inspection and testing in addition to normal sprinkler tasks.
Our 24/7 line connects you with an on-call coordinator who can dispatch a technician, help you plan fire watch, and document the impairment for your records.